Switching station for mains priority circuit UPS operation US-16 230V 16A 3600W

OffgridtecSKU: 8-01-010711


Due to the holidays and the subsequent inventory, there may be delays in delivery times. Parcel deliveries will be made until December 23 and between the holidays, while freight deliveries will be possible in isolated cases until December 23 and again from January 7, 2026. We apologize for any inconvenience and thank you for your understanding.

Price:
Sale price€96,24 EUR

Tax included Shipping calculated at checkout

Description

Versatile all-rounder

Offgridtec switching stations enable you to operate 230V consumers from two different voltage sources without interference. Typically, this is a voltage converter or the public power grid

With the priority circuit, you can determine which power source should be used preferentially - if this voltage source fails, the system switches to the backup power source without interruption.

The use of the highest quality relays guarantees on the one hand a particularly precise switching threshold, and on the other hand your voltage converter is optimally protected against external voltage being fed back.

Recommendations for use:

  • Solar island systems
  • Service and commercial vehicles
  • mobile homes and caravans
  • Sailboats and other watercraft

Technical specifications:

  • Input voltage: 230VAC, 50/60Hz
  • Input current (max): 16A
  • Output voltage: 230VAC, 50/60Hz
  • Power (max): 3600VA
  • Switching time: 1-2 seconds
  • Fuse: F 16A / 250V
  • Protection: overload, short circuit
  • Housing: plastic
  • Degree of protection: IP55
  • Inputs: screw terminals, binding post
  • Dimensions: (LxWxH): 160 x 145 x 77mm
  • Weight: 450g

Application example 1 - mains priority circuit:

  • The 230 V AC network is connected to input AC2 (higher priority).
  • This means that the battery is spared and the inverter is protected against external voltage at the same time.
  • Input AC1 only switches on the power supply from the battery and inverter when AC2 is de-energized

Application example 2 - inverter priority circuit:

  • The inverter is connected to input AC2 (higher priority).
  • This means that the current is primarily taken from the battery via the inverter (e.g. when using solar stand-alone systems)
  • Only when the inverter switches off due to deep discharge protection is the 230 V AC network switched on via input AC1

Delivery time: 1-3 working days

Scope of delivery:

  • 1x switching station
  • 1x PE connection terminal
  • 1x user manual, DE, GB, FR, NL