Power Supply
|
|
Input supply voltage
|
10 to 35 V DC
|
|
Input supply current
|
325 mA max at 12 V DC (all outputs fully driven into 100 Ohm loads)
|
|
Input protection
|
Continuous reverse polarity, transient overvoltage, and ESD protection
|
|
Power indicator
|
LED, blue – indicates that the unit is operating correctly
|
|
Input power connection
|
Pluggable 2-way screw terminal, 5.08 mm pitch
|
|
NMEA 0183 Port – Listener & Talker
|
|
Number of Listener / input ports
|
2 isolated NMEA 0183 Listeners
|
|
Number of Talker / output ports
|
12 isolated NMEA 0183 Talkers
|
|
Compatibility
|
Fully NMEA 0183, RS422 & RS232 compatible. RS485 Listener compatible
|
|
Speed / baud rate
|
4800 to 38400 bps
|
|
Talker output voltage driver
|
>= 2.2 V (differential) into 100 Ohm
|
|
Talker output current driver
|
20 mA maximum per output
|
|
Talker output protection
|
Short circuit and ESD
|
|
Talker data indicator
|
LED, orange (flashes at data rate)
|
|
Listener input voltage tolerance
|
-15 V to +15 V continuous, -35 V to +35 V short term (< 1 second)
|
|
Listener input protection
|
Current limited, overdrive protection up to 40 VDC and ESD protection
|
|
Listener data indicator
|
LED, green (flashes to indicate a valid input)
|
|
Connections
|
Pluggable 2/3-way screw terminals, 5.08 mm pitch
|
|
Serial Interface
|
|
Compatibility
|
RS422 and RS232 compatible. RS485 Listener compatible
|
|
Speed / baud rate
|
4800 to 115200 bps
|
|
Output voltage drive
|
>= 2.1V (differential) into 100 Ohm
|
|
Output current drive
|
20mA max.
|
|
Output protection
|
Short circuit and ESD
|
|
Input voltage tolerance
|
-15 V to +15 V continuous, -35 V to +35 V short term (< 1 second)
|
|
Input protection
|
Current limited, overdrive protection up to 40 VDC and ESD protection
|
|
Data indicators
|
LEDs: Green = Receive, Orange = Transmit
|
|
Connections
|
Pluggable 3-way screw terminals, 5.08 mm pitch
|
|
Ethernet Connection
|
|
Host interface
|
10/100BaseT, automatic polarity detection
|
|
Supported protocols
|
TCP/IP for configuration and firmware update
|
|
TCP/IP and UDP for NMEA 0183 communication
|
|
Indicators
|
Green = Link/Activity, Yellow = 100 Mbit/s
|
|
Connector
|
RJ45
|
|
Isolation
|
|
NMEA 0183 Listener
|
OPTO-isolated, Hi-Pot tested to 1000V
|
|
NMEA 0183 Talker
|
Uses IsoDrive TM, Hi-Pot tested to 1000 V
|
|
Serial interface
|
Uses IsoDrive TM, Hi-Pot tested to 1000 V
|
|
Alarm relay
|
Hi-Pot tested to 1000V
|
|
Ethernet connection
|
2kV for 60s
|
|
Mode Inputs
|
|
Input voltage range
|
0 to 35 V DC
|
|
Protection
|
Transient overvoltage and ESD protection
|
|
Connections
|
Pluggable 2-way screw terminals, 5.08 mm pitch
|
|
Alarm Output |
|
Contacts
|
Common, normally open, and normally closed
|
|
Alarm indicator
|
LED, red indicates a valid alarm condition
|
|
Contact ratings
|
35VAC / 50VDC
|
|
Connections
|
Pluggable 3-way screw terminals, 5.08 mm pitch
|
|
Mechanical
|
|
Housing material
|
316 stainless steel
|
|
Dimensions
|
210 mm (W) x 128 mm (H) x 27 mm (D)
|
|
Weight
|
530g
|
|
Mounting
|
Bulkhead mounting or DIN rail mounting (DIN Kit 1)
|
|
Approvals and Certifications
|
|
EMC
|
IEC 60945:2002-08, DNVGL-CG-0339:2019 & IACS UR E10 Rev7
|
|
Compass safe distance
|
750 mm
|
|
Type approval certificate
|
RINA
|
|
Operating temperature
|
-25 to +70 °C
|
|
Storage temperature
|
-40 to +85°C
|
|
Relative humidity (RH)
|
95% at 55°C
|
|
Environmental protection
|
IP40
|
|
Warranty
|
5 years
|